Making a Multi-function Water Level Controller Circuit

The following multi-function water level controller circuit post is based on the suggestions expressed by Mr.Usman. Let's learn more about the requested modifications and the circuit details.

The Suggestion:

"Hi Swagatam,

The concept of this circuit looks good. May I suggest a couple of other desirable features?

1) To protect the motor from potential overheating (or as a safety feature) can u add an automatic shutdown timer? If the motor is running for one hour (or 1.5hrs or 2-hrs) and the water level does NOT reach the level-sensor, the motor should be automatically stopped. Of course, it can be re-started manually by pushing the start button again.

2) Can the motor be manually stopped at any time? For example, what if one wants to water the lawn (or wash the car) for a few minutes using high pressure water directly from the motor?"


Thanks very much!

Your suggestions are interesting!

I think I have discussed these issues in the following artricle:

http://homemadecircuitsandschematics.blogspot.in/2012/03/dc-motor-protector-circuit-over-voltage.html

However instead of a timer I have used a temperature sensor circuit for tripping the motor if it starts getting hot.

The motor can be manually stopped by shorting the base of T3 to ground. This can be done by adding a push button across these terminals. 

So the upper push button may be used for initiating the motor while the lower button may be used for stopping the motor manually.






Thanks Swagatam for a prompt reply. I've found another circuit on your blog (April 20th post) that is closer to what I have in mind.

http://homemadecircuitsandschematics.blogspot.com/2012/04/semi-automatic-water-level.html

I want a slightly different control logic in the above circuit:

Motor START Logic:
Manual push button (already implemented)

Motor STOP Logic:
1) Water level reaches a pre-determined level (as implemented in April 21st post), OR
2) A pre-determined time has lapsed (e.g. 30, 60 or 90 mins, this requires a long time-delay/counter), OR
3) Manual stop (manual override), OR
4) Power faliure (load shedding), this is implemented by default!

So I guess, the STOP logic (1, 2 and 3) can be configured to the base of T1 (in your April 20 post) and it should work. Pls comment, and if you have time maybe you can make a new post!

Thanks
Usman



The Design:

Let's analyze the above requirements and check how they have been implemented in the following diagram:

1) Water level reaches a pre-determined level: Point A and B may be appropriately fixed inside the tank for regulating this function. Since point B is situated at the bottom of the tank, remains connected with the water permanently, now as the level rises and comes in contact with point A, the positive potential from point A connects with point B, which instantly reset pin#12 of the IC, switching OFF the relay and the entire system.

2) A predetermined time has lapsed: This feature is already present in the below given circuit. The timing outputs can be increased to any desired extents simply by increasing the values of P1 and C1.

3) Manual stop (manual override): This feature is actuated by SW2, pressing which resets the IC pin#12 and the entire circuit. 

4) Power failure (load shedding): During a possible power failure or instantaneous power "blinks", the IC needs to be supplied with the required supply voltage so that the timing does not get interrupted. This is very simply done by adding a 9 volt battery to the circuit.

 As long as normal power is present, the cathode of D3 stays high keeping the battery switched OFF from the circuit. The moment power fails, the cathode of D3 becomes low, providing a way-in to the battery power which smoothly replaces the supply to the IC without causing any "hiccup" to the counting operation of the IC.



Parts list for the above explained multi-function water level controller circuit

R1= 1M, 1/4 watt
R3 = 1M
R2, R6 = 4K7
R4 = 120K
R5 = 22K
P1 = 1M preset horizontal
C1 = 0.47uF
C2 = 0.22uF disc ceramic
C3 = 1000uF/25V
C4 = 100uF/25V
D1, D2, D3, D4 = 1N4007,
Relay = 12V/SPDT
SW1,SW2 = Bell push type of button
IC1 = 4060
T1, T2 = BC547
TR1 = 0-12V/500mA
BATT - 9V, PP3

Water level buzzer indicator circuit

The following circuit of a water high level and low level indicator circuit was requested by Mr.Amit. Please read the comments given below to know regarding the exact specs of the requested circuit.




Circuit Description

The above shown water high and low level buzzer indicator circuit may be understood with the following points:

Point C which is connected to the ground or negative of the supply rail is kept immersed in the tank water at the bottom level such that the water present in the tank is always held a logic low.

Point B is the low level sensor point which must be positioned near the bottom of the tank, distance may be set as desired by the user.

Point A is the high level sensor, which should be held somewhere at the top of the tank as per user preference.

When the water level reaches under the point B, point B goes high due to R6, making the output of N4 high and consequently producing a low at the output of N5....the buzzer B2 starts buzzing. 

However in the meantime C2 starts charging up and once it's fully charged inhibits the positive potential at the input of N5.....the buzzer is switched OFF. The time for which the buzzer remains On may be determined by the values of C2 and R5.

In an event the water reaches the top level of the tank, point A comes in contact with the low logic from the water, output of N1 becomes high and the same process is repeated as explained above. However this time B1 starts beeping, only until C1 gets fully charged.


Five gates from the IC 4049 have been utilized here, the remaining one unused gate input should be grounded for maintaining stability of the IC.

Parts List

R1,R6 = 3M3
R3,R4 = 10K
T1, T2 = 8550, or 187, or 2N2907 or similar
C1,R2 = to be selected for setting up buzzer on time
C2,R5 = to be selected for setting up buzzer on time.
N1---N5 = IC 4049
B1,B2 = Loud piezo buzzers

56 comments:

  1. Excellent!! It covers all the design parameters!

    A few comments:

    1) Instead of P1, I think one can use three (or four) resistors connected to a 3-position (or 4-position) slider switch (just like the ones on many small multi-voltage DC adapters). If the resistor values are chosen carefully, we can have fairly accurate time-out values. This way you can eliminate the guess-work/calibration of P1.

    2) Personally I don't like mixing water and electricity (even small voltages). Point-B, which is held at about 15-18V DC, is always submursed. I am thinking on the lines of a mechanical-button (like a cheap float switch, or a mercury switch) that can be connect to points A and B.

    3) Side note: One idea that is stuck in my mind is to make a (ultra-cheap) water level sensor using a ping-pong ball in a uPVC-pipe. This would be a fail-safe mechanical design, will take care of ripples and splashes in the tank and will have a service life of many decades! This assembly can even be fixed outside the tank (thru the water supply pipe.) So far so good, but the key question remains how to sense the height of the floating ball relative to the top of the pipe? Any ideas? Can we use light (LEDs)? Pressure? Range sensor? It has to be very cheap at the same time.

    Thanks
    Usman

    ReplyDelete
    Replies
    1. Thanks Usman!

      I appreciate your response!

      A water level indicator circuit has been covered in the following article, can be used in conjunction with your third suggestion:

      http://homemadecircuitsandschematics.blogspot.in/2012/04/make-this-water-level-indicator-circuit.html

      Regards.

      Delete
    2. sir this multi functional water tank circuit is full automatic, means this circuit is able to on and off the pump automatically....thanks hundal76@gmail.com

      Delete
  2. Dear Mr. Swagatam,

    can you pleaes make circuit which do as follows.

    i have 250 liter overhead water tank. what i want is when we start filling the tank with water & when water level reachs to 90% { or consider hight of tank which is abt. 3.5' } a siren shoud start for 3 times so we can come to know that the tank is about to full { otherwise it waste lots of water } and 2nd is when the water level is about 25% again the siren should start for 3 times so we can come to know that its time to fill up the water tank.
    {if possible , please make cercuit that works on battery as it is not possible to give power supply there }

    Thanks is advance.

    Regards,
    Amit Desai.

    ReplyDelete
    Replies
    1. Dear Amit,

      Three times beeping siren will be difficult to configure and would make the design complicated.

      A siren which would sound for a few seconds and then stop can be made though.

      I'll try to design it and update it here soon.

      Regards.

      Delete
    2. Dear Mr. Swagatam,

      Thanks , seconds based beeping is woluld be also a good solution.
      please try it for me.

      Regards,
      Amit Desai.

      Delete
    3. Dear Amit,

      I'll do it asap...

      Delete
    4. Hi Amit,
      I've the updated the required circuit in the above article....

      Delete
    5. Dear Sir,

      thanks a lot.

      Regards,
      Amit Desai

      Delete
  3. Dear Swagatam,

    On similar lines for a water level buzzer can we use a push button switch to mute the buzzer and once the water level goes down the buzzer will get automatically reset and ready for next operation? Please help me on such a circuit, Can we build it using just BJT's?

    Best regards
    niranjan

    ReplyDelete
    Replies
    1. Dear Niranjan,

      The buzzer circuit shown above automatically stops buzzing after a few seconds or more depending upon the values of the specified R and C. so a switch is not required here.

      And also the circuit resets for the next cycle once the water level goes below the set points.

      So everything's there in the design as required by you.

      BJTs won't produce accurate results and the circuit might get too lengthy.

      Regards.

      Delete
  4. Hy

    i new comer in this field with little bit knowledge

    recently i purchase First Figure Component but instead of

    C1 = 0.47uF i got the 474k/450v and C2 = 0.22uF i got 224 ceramic capacitor

    So Please Advise me can i use this two capacitor

    and For the Point A and Point B which is going to Water what i used there a simple wire or anything else

    and what type and how much max rating water pump i can operate by using this

    Thanks

    ReplyDelete
    Replies
    1. Hi,

      You could have used ceramic for C1 also because 450V is unnecessarily big.

      But anyway, both the capacitors will work, no issues.

      Simple wire outlets will do, however it would be better to put them neatly over a plastic stick and clamp the metal outlets at the relevant levels inside the tank, use brass screws and attach them to the wires outlet terminals and the screws over the plastic stick.

      The relay contacts should be matched with the pump max current otherwise the relay may burn due to overload.

      Delete
    2. Hy Swagatam Thanks for reply

      when i connect the circuit i got ac supply in water tank as well circuit cant work and how to test a relay also how to know ic proper working

      one more que the 9v dc supply is compulsory needed is not

      any idea

      Delete
  5. hy swagatam

    i also new in this field so i would like to know work function of this circuit.

    interested to know how i identify the ic & relay terminals

    ReplyDelete
    Replies
    1. The left pin starting at the left of the notch on the IC is pin#1 while the pin at the right is the last pin of the IC.

      for understanding relays you may refer to this article:

      http://homemadecircuitsandschematics.blogspot.in/2012/01/how-to-understand-and-use-relay-in.html

      Delete
  6. Hy

    Is this perfect ic no for this cd4060be

    Because of I use this ic but this circuit can't run in any condition so any idea where I miss

    ReplyDelete
    Replies
    1. Hi,

      Yes the diagram is perfect!

      You should make and check the 4060 timer section separately, and then integrate it with rest of the stages.

      Delete
  7. hy swagatam

    i little bit confuse regarding a ic

    for the ic 4060 u displaying a real pin number of ic or out put sequence of ic because when i read

    http://en.wikipedia.org/wiki/4000_series

    in this on 4017 decade counter there is two types of number

    first one is Pin number & Second is Name

    that's y i confused about

    ReplyDelete
    Replies
    1. I have put real pin numbers...... for indicating sequence order I would have used Q1, Q2, Q3......etc.

      However there's no sequence indicated here because it's just a timer circuit with a single output at pin#3.

      Delete
  8. Hy Swagatam

    is this tested circuit

    and can u provide a pcb design for this circuit

    ReplyDelete
    Replies
    1. It's not tested but according to me it will work, PCB design will be difficult for me to provide... sorry.

      Delete
  9. hy

    When i connect this circuit its start up but when point A & B Connect its cant stop the circuit

    instead of motor i used a lamp &Instead of water tank i manually connect the Lead A & B

    any idea why this happen

    ReplyDelete
    Replies
    1. Hi,

      You are correct, the circuit needs correction, I'll do it after sometime, check back soon..

      Thanks!

      Delete
    2. It's done now! the parts list has also been modified appropriately....

      Delete
    3. hy Swagatam

      According to your modification i changed connection as well parts also but still when i switch on ac power supply and lead A & B Not connected its glow the Bulb but when manually i connect lead A & B it's cant stop bulb glow

      Please if possible then do something

      because in my new home i want to use this circuit

      Delete
    4. You mean the relay does not trip off on connecting points A and B???

      This cannot happen now, because when we join A and B, T1 receives a positive potential at its base and switches ON.

      With T1 switched ON, T2 base voltage becomes zero, which in turn switches OFF the relay and also the entire circuit along with the load.....please check your circuit connections once again.

      Delete
    5. Hy Swagatam

      i checked my circut connection is complete as per your new connection diagram but it still can't stop the relay

      also can we add a new level in this means after a some water level goes down the motor start because in this i figure out if water level goes down suddenly motor start but i think its rapidly start and stop motor a lot time in a day

      that's why i think we have to make a Lower Level after that motor start and when reach top its became stop and vice-verse

      Delete
    6. I think T2 may be faulty in your circuit.

      I am sorry I did not understand your need, please explain it more clearly....

      Delete
    7. there is three level in the tank 1) Bottom 2) Middle 3) Top

      i need Motor Start after Water level Go down Below the Middle Level And Also when Motor Start its has to stop on the Top Level not at Middle Level

      Delete
    8. I think the following circuit might help:

      http://homemadecircuitsandschematics.blogspot.in/2012/09/simple-water-level-controller-circuit.html

      Delete
  10. Good day sir,
    I need circuit diagram for water level controller which should be set in the underground tank which collects the water from the municipal.
    that is when the water level rises and attain a particular stage in the underground tank the motor should be switched on and the water if drain the motor should be set off. And if the overhead tank get overflow before..
    it should be neccessary that the motor should set off that’s my requirements sir.
    Thanks in advance.

    ReplyDelete
    Replies
    1. Good day Vi,

      I could not understand this sentence:

      "and the water if drain the motor should be set off. And if the overhead tank get overflow before"

      Delete
  11. Thanks for your instant reply sir,
    You are wonderful in giving some awesome circuits for us. i am coming to my needed circuit design.

    I had done many of your circuits sir.

    I saw a circuit in your bright hub page sir that is my exact requirement with some additional functions i am asking a circuit sir.

    * I am getting tap water and storing in the underground tank now i am manually switching the motor to fill those water in the overhead tank so I thought that a automation work could do this instead of man

    circuit requirement:
    1. when water rises a certain level in the underground tank the motor should be switched ON and when the water attained a low position in the underground tank the motor should be switched OFF.
    2. During this process if the overheadtank overflows then the total system should be switched OFF automatically using an relay.

    Sir you have done these circuits seperately I think. I need a conjunction of those circuits sir.

    Sorry for my bad English I think it will disturb you lot.

    Thanks in advance sir.

    ReplyDelete
    Replies
    1. Thanks V1,

      you will have to make the following circuit first:

      http://homemadecircuitsandschematics.blogspot.in/2011/12/how-to-make-simple-water-level.html

      then add another transistor stage to it in the following manner:

      use a BC547 transistor.
      connect its collector to the base of the relay driver transistor.
      emitter to ground.
      connect its base via a 1K resistor somewhere at the overflow point of the overhead tank.

      also connect a positive supply link at the bottom of the overhead tank so that it stays immersed in the tank water.

      The above set up will hopefully fulfill your application.

      Delete
  12. Thanks once again Sir.
    Kindly i will be back after my exams sir
    Thank You for your help and your excellent blog Sir.

    ReplyDelete
  13. Hello sir,
    Thanks for your great circuits.
    I had made the above one and it is working fine.the timer section and the overflow sensing section is working perfectly allright. the only problem is with manual stop switch accross .22uf which is not giving any response.i had used two .1uf/400v ppc type cap.in parallel.
    Help me to get out of this problem
    Thanks

    ReplyDelete
    Replies
    1. Hello Avijeet,

      yes the position of the switch is incorrect.

      connect the switch across the base of T2 and ground, this will instantly stop the motor.

      Thanks

      Delete
    2. Thanks sir,
      I had made the corrections and now it is working fine.
      #Sir want to ask u that i had to drive the circuit only for 10 to 20 min so 1m preset is giving huge fluctuations to set it for such a small time period.could i reduce the value of 1m preset without changing capcitor value.
      #how could i use 6-0-6 value trfo to get 0-12v for above circuit.
      Thanks

      Delete
    3. Hi Avijeet,
      You can any value above 10k for the 1M position and get any desired timing output.

      Alternatively you can also experiment with the capacitor for the same.

      Use the outer taps of the trafo and connect them with the bridge or whatever rectifier stage you are using, leave the center tap alone, it won't be required.

      Delete
  14. 1. multifunctional circuit is worked or not.
    2. can i operate 2hp submersible on this circuit.
    3. this circuit start/stop motor automatically.
    4. p1=port or something else..

    ReplyDelete
    Replies
    1. This circuit is not fully automatic, use the following circuit which suits your application:

      http://homemadecircuitsandschematics.blogspot.in/2011/12/how-to-make-simple-water-level.html

      Delete
  15. i make a water level monitor using a remote controlled toy car circuit.
    It can can monitor water levels and alarm when tank is full.But i can't to controll the motor
    Pls help me?

    ReplyDelete
    Replies
    1. show me the full details, i'll check it.

      Delete
  16. Hi Swagatam,

    You are having one of the best blogs which hits the nail right at the head. I am trying to make a water level indicator, but with data logging to an SD card to collect some data for research. I just wanted some advice on sensors. I would like to have some kind of sensors which won't corrode easily. Whats your experience with these stainless steel or brass probes or what other alternatives do you suggest. I was also thinking of using ultrasonic distance sensor, but again I am worried that it might also corrode due to humidity in the tank. What do you say ?

    Regards
    Raman

    ReplyDelete
    Replies
    1. Hi Raman,

      Thank you very much!

      This question has been asked by many readers here, and as per my thinking I have suggested them to use use brass terminals tinned thoroughly with solder wire. According to me tin will remain unaffected from corrosion, but I am not sure about algae or other such formation on its surface which probably has no remedy.

      Using frequency with the sensors is one option but since the receiving sensors are passive we cannot introduce frequency in them,so this option doesn't hold good either.

      Delete
    2. Thanks for your reply.

      I think there is a strong possibility of lead poisoning if solder comes in contact with drinking water. Already there are thousand other things which could kill us and I don't think we should add one more :-)

      I think some kind of contactless sensor should be a safe bet. I read somewhere people using sensors from automatic washing machines which could measure water pressure. But these sensors will surely be difficult to find. I'll keep scratching my head for more ideas.

      Regards
      Raman

      Delete
    3. Lead atoms would be tightly bonded inside the solder metal so there's little chance of it getting dissolved, and even if it does it will be in negligible quantity. But anyway safety is always first so it's better to avoid it and find some other similar yet safe alternative.

      Regards.

      Delete
  17. Sir will the battery used in the first schematic be drained all the time by the ic and the incorporating circuitry????? Even the mains is present????

    ReplyDelete
    Replies
    1. As long as mains power is present battery will not drain, when mains fails the IC will consume 5mA, and the relay 40mA (when in ON position) from the battery

      Delete
  18. Sir can i use a 12V 10 A relay for a half hp pump?????
    I have found in some articles that the initial driving current goes to 6-7 times the running current for a motor. So eventhough mine is a HALF Hp one drawing nominal current of 380W/230V= 1.6 A, it may have 9.6 to 11.2 A of starting current.
    Also i have noticed in my relay the specifications written which i am giving below


    50/60 Hz
    7A 250V ~ | 10A 125V AC
    12A 125V --- | 10A 28V DC


    I am not at all familiar with electronics but i a m very interested to do simple projects like this. I couldn't understand the exact meaning of the specification written here. So please help in this issue?
    May i have to change the relay or not?


    Sorry for the bad english

    ReplyDelete
    Replies
    1. Hello Kajal,

      Yes you will have to replace the existing relay with a 30amp relay or you may also try using a triac instead.....a BTA41/600 could be tried.

      Delete
  19. Hi Sawagatam,

    How do you post a new request on your blog? This request needs a new thread.

    Can you help me with this problem: In a basement sump, there are two submersible pumps with float switches (P1 and P2) installed to achieve some level of redundancy. In order to use both pumps equally, we want to alternate between P1 and P2 whenever a preset water level is reached. That is, the first time the preset level is reached P1 should start and pump the water out. Next time when the preset level is reached P2 should start and pump the water out. On next occasion it will be P1's turn and so forth. What we need is an "alternating" relay control running P1 and P2 turn by turn.

    ReplyDelete
    Replies
    1. Requests can be posted through comments only, exactly as you have done.

      I have understood your requirement, I will try to update it soon in my blog and inform you.

      Delete

Readers are requested not to include external links while commenting. For consulting a diagram, upload it on Google Drive and provide the link here.